Documented incidentIncident 2021-10-04Meta (Facebook)Engineering postmortem

Backbone maintenance command disconnects Facebook's data centers and locks out recovery tooling (Meta, 2021)

A command issued to assess global backbone capacity unintentionally took down all the connections in Facebook's backbone network.

What happened

  • A bug in the audit tool designed to prevent such commands stopped it from properly blocking this one.More details about the October 4 outage
  • Recovery was slow because engineers could not use normal access paths and DNS also failed, which required onsite intervention at heavily secured data centers.More details about the October 4 outage

The failure pattern

Watch the pattern: Global change without a staged rollout

Safeguards that address it

CollectSEA's engineering analysis of what would have prevented or contained this failure.

  • Test the guard that is meant to stop dangerous commandsAudit tools need their own tests and a second independent check for changes that can disconnect the network.
  • Keep recovery paths independent of the thing being recoveredEnsure out-of-band access and DNS-independent tooling exist so a network failure does not lock operators out.